C-105, Ansa Industrial estate,
Saki Vihar Rd, Saki Naka, Mumbai-400 072
Mon - Sat 8.00 - 18.00
Sunday CLOSED
(+91) 22 4015 1020

Series N – Hydro Pneumatic Cylinder

N series

Series N – Hydro Pneumatic Cylinder

‘N’ series Hydro-Pneumatic Cylinders are independent power units that can be purchased separately and further integrated in to larger systems.  They are available in tonnages starting from 8 tonne and going all the way up to 45 tonnes.  The standard travel lengths provided are 50 mm, 75 mm, 100 mm & 150 mm with power stroke lengths of 6 mm, 12 mm or 24 mm . Below are the list of models with details of their configurations.

N series

Series N Hydro Pneumatic Press Cylinders

 
MODEL No.TONTotal StrokePower StrokeQ (NL)
AIR CONSUMP.
N 086-757.25752452
N 086-1007.251002455
N 086-1507.251502462
N 151-501550633
N 151-751575638
N 151-10015100642
N 151-15015150646
N 154-7515751264
N 154-100151001272
N 156-7514.75752492
N 156-10014.751002496
N 156-15014.7515024104
N 301-503050656
N 301-753075660
N 301-10030100664
N 301-15030150672
N 304-7530751290
N 304-100301001299
N 304-1503015012112
N 451-100451006110
N 451-150451506122
N 451-200452006134
N 454-1504515012187
N 454-2004520012199
MODEL NO. DESCRIPTION ORIFICE mm PORT BSP THRDS BSP WEIGHT (Kg.) SEAL KIT NO.
RS04 1/2” BSP ROTORSEAL COUPLING Ø19.00 3/4″ 1/2″ 0.530 SKRS04
RS05 3/4” BSP ROTORSEAL COUPLING Ø19.00 3/4″ 3/4″ 0.540 SKRS05
RS06 1” BSP ROTORSEAL COUPLING Ø25.00 1″ 1″ 0.870 SKRS06
Output Forces (Kgf.) at Inlet Air Pressure of 5 Bars
Tonnage 8T 14.75T 15T 30T 45T
Approach275435475435680
Power858514750148002917544950
Return425105082511601300

To Calculate Compressor Power Capacity

1 HP = 120 litres of Free Air (NL) Per Minute at 5 Bars.

N = Number of Cycles per minute

Q = Free Air Consumed Per Cycle (From Chart) in Normal Litres (NL)

Power Required

Power Required = Q × N / 120 (H.P.)  or  (Q × N / 120) × 0.746 (KW)

To Calculate the Cost of Electricity

Example :- A 15 Tonne, 50 mm stroke with 6 mm power stroke press is used at 5 bars to cut Aluminium washers from a sheet at the rate of 10 pieces per minute.

  1. From above chart model N151-50 cylinder consumes 33 NL of air per cycle.
  2. @ 10 strokes/min air consumption = 33 × 10 = 330 NLPM
  3. Electric Power used = 330 ÷ 120 = 2.75 HP ≈ 2.05 KW/min
  4. Power used per hour (KWH) = 2.05 × 60 = 123 KWH
  5. Cost of electricity @ Rs 4.5 per KWH = 123 × 4.5 = Rs 554
  6. Cost of electricity per cut piece (10 × 60 = 600/hr) = 554 ÷ 600 = 0.92 i.e. Rs. 0.92 per piece

Enquire Now